What Are The Maintenance Intervals For Dry-mix Mortar Equipment?

Aug 04, 2026

Leave a message

Standard maintenance intervals by frequency:
Daily Maintenance (Daily/Per Shift):Clean out residual material; check the condition of pneumatic components, instruments, and lubrication points; perform after the completion of each shift.
Weekly Inspection (Once a week): Check drive chains and belt tension; tighten bolts across all assemblies; test the weighing system for zero-point drift.
Monthly Maintenance (Once a month): Replace or replenish lubricant for gearboxes and bearings; clean dust collector filter bags; calibrate the accuracy of metering scales.
Quarterly Inspection (Once every 3 months): Conduct a comprehensive inspection of mixing paddles and liner plates for wear; clean pneumatic system filters; test the performance of air compressor safety valves.
Annual Overhaul (Once a year): Dismantle the main mixer unit to inspect the main shaft and sealing system; fully calibrate the batching system; replace severely worn parts; perform deep cleaning and insulation testing of the electrical system.